Heat Exchangers - Sorted by Diameter
Inventory Number Manufactured By Year Manufactured TEMA Type Diameter End / End Length Duty Shell Design Press. (PSI) Tube Des. Press. (PSI) TubeArea
E-484 Maloney Crawford 1966 u-tube

oil bundle
100
E-471








E-142 Superior
INLET GAS COOLER
28' 0"
775 75 2794 SQ. FT.
E-464 Standard Refrigeration




250 165
E-463 Standard Refrigeration 1998



165 165
E-0








E-460 Western Supply Co


20'



E-477 Alco 1995



125 230
E-086 BROWN FINTUBE
HAIR PIN EXCHANGER 003" 20' 0"
600 600 73
E-189 Brown Fintube 1950 HAIR PIN EXCHANGER 003" 24' 0"
500 500 100.9 Surface Sq. Ft.
E-191 Brown Fintube 1965 HAIR PIN EXCHANGER 003" 24' 0"
500 500 140.9 Surf Sq. Ft.
E-059 BROWN FINTUBE 1981 HAIR PIN EXCHANGER 003" 19' 6"
800 510
E-062 Brown Fintube 1967 HAIR PIN EXCHANGER 003" 13' 3"
500 1300
E-080 *BROWN FINTUBE
HAIR PIN EXCHANGER 003" 20' 3"
600 600 121
E-066 Brown Fintube 1967 HAIR PIN EXCHANGER 003" 25' 3"
835 835 157
E-092 Brown Fintube 1967 HAIR PIN EXCHANGER 003" 20' 3"
500 1000 20
E-096 Brown Fintube 1980 HAIR PIN EXCHANGER 003" 10' 0" 99,536 700 500 71
E-097 Brown Fintube 1980 HAIR PIN EXCHANGER 003" 15' 2" 54,000 700 650 99
E-107 Brown Fintube 1980 HEAT EXCH 003" 10' 2" 82,000 X 1.2 B.T.U. / HR 500 500 68
E-255 Brown Fintube 1967
003" 41' 201 SQ. Ft. 500 500 201
E-263 Brown Fintube 1993
003" 18' 175 Sq. Ft. 600 600 175
E-329 Brown Fin Tube 1959
003" 21' 7" glycol / glycol exchange 850 850 140
E-336 Thermal Design 1974 N/A 003" 11'
500 500 10 3
E-290 Brown Fintube 1970 u-tubes 003" 30'
500 500 212 Square feet
E-286 Shell & Tube 1970 U- tubes 003" 20' 202 Sq. Ft. 300 500 202
E-067 B L H CORP. 1964 HAIR PIN EXCHANGER 003" 20' 0"
650 1000
E-370 R. W. Holland Inc. 1981
003" 16'
900 900
E-337 Thermal Design 1974
003" 11'
500 500
E-145 Brown Fintube 1967 HAIR PIN EXCHANGER 003" 24' 0" 550,000 500 500 20 SQ. FT.
E-500 Bes-Tex 1984 U-Tube 003"x1.5"

100 1200 1200
E-501 Bes-Tex 1984 U-Tube 003"x1.5"

100 1200 1200
E-499 Bes-tex 1984 U-Tube 003"x1.5"

100 1200 1200
E-045 Brown Fintube 1969 Fintubes 004" 31' 0" Surface area 394 sq. ft. 500 500 394
E-094 Brown Fintube 1969 HAIR PIN EXCHANGER 004" 30' 5"
500 500 394 Square Feet
E-245 Brown Fintube 1961
004" 20'
440 500
E-348 Holland 1994 hair pin exchanger 004" 17' 152,631 260 675 150 square feet
E-179 Brown Fintube 1988 HAIR PIN EXCHANGER 004" 12' 0"
400 200 38
E-047 Brown Fintube 1980 Heat Exchanger 004" 10' 0"
500 500
E-498 Rama 1997
004"x8" 20' glycol/gas


E-303 Bronco Mgf. 1976 U-tubes 006" 30' 2556 Sq. Ft. 50 50 2556
E-327 Alco Products 1982
006" 12'
100 150
E-323 TMT 1984 BEM 007" 24' Gas/ Gas Exchanger 1100 1100
E-072 KEMCO 1964 HEAT EXCH. 008" 7' 8" 767,000 200 300 86
E-040 Bas Tex 1988 Heat Exchanger 008" 27' 0" 2,500,000 75 1100 1118
E-325 TMT 1983 BEU 008" 8' Deethanizer Reboiler 150 500
E-238 Tri-Ex 1967 Bem 008" 20'
200 600
E-070 KEMCO 1964 HEAT EXCH. 008" 9' 8" 619,000 200 125 107
E-112 JET-VAC

008" 10' 0"


96 sq. ft.
E-395 Natco 1990 Glycol 008" 10'
150 150
E-465 Bas-Tex

008" 22'
700 700
E-297 Shell & Tube 1970 BEM 008" 24' 642 Sq. Ft. 200 1100 642
E-144 Tri-Ex 1968 BEM 008" 32' 0" SIZE 8-384 275 675 341 ft2
E-280 TMT 1983 BEM 008" 17' 141 Sq. Ft. 300 100 141
E-277 TMT 1983 Bem 008" 17' 141 Sq. Ft. 300 100 141
E-146 Tri-Ex
BEM 008" 10' 0"
180 450 SIZE 67330
E-154 Slagle Mfg. Corp. 1967 BEU 008" 24' 0" 2,878,000 375 125 151 sq ft
E-394 Thermal Eng 1990 Glycol Ex. 008" 20' 6" 2 150 150
E-279 TMT 1983 Bem 008" 17' 141 Sq. Ft. 300 100 141
E-188 Western Suppy 1960
008" 5/8" 16' 0"
300 125 151 Surface Sq. Ft.
E-324 TMT 1983 BKU 008"-16" 20' Chiller 50/250 1100 N/A
E-412 Heat transfer systems 1984 BKU 008/24 20' 76 square feet 250 100
E-503 Tulsa Multi tube 1984 BEM 010" 32' Product Exchanger 450 1200
E-287 Shell & Tube 1970 Bem 010" 14' 590 Sq. Ft. 200 275 590
E-288 Shell & Tube 1970 BEM 010" 14' 590 Sq. Ft. 200 275 590
E-212 Kemco 1988 Refrigerant sub. Cooler 010" 23' 0"
250 75 928
E-282 Shell & Tube 1970 BEM 010" 20' 823 Sq. Ft. 700 100 278 Bare tube area
E-218 Patterson-Kelly Co. 1982
010" 12'
475 50
E-033 HEAT EXCHANGERS INC. 1966 TUBES 010" 30' 0"
250 400 482 sq ft
E-452 Ametek Inc ? 1-R-2 010" 6'
100 100
E-417 Heat transfer systems 1984 BKU 010/26 15' 96 square feet 615 250
E-411 Heat Transfer systems 1984 Bku 010/26 19' 127 square feet 615 400
E-414 Heat transfer systems 1984 BKU 010/26 19' 127 square feet 275 615
E-415 Heat transfer systems 1984 BKU 010/26 19' 127 square feet 275 615
E-207 Kemco 1966 NEN 012 3/4" 24' 0"
160 75 1380
E-208 Exell 1966 NEN 012 3/4" 24' 0"
100 75
E-489 Shell &Tube 1983 BKU 012 x 25 12' Gas Chiller 300 1100 255
E-504 Tulsa Multi tube 1984 BEM 012" 8' Sub Cooler 300 300
E-454 Heat Exchanger 1966
012" 8'
300 150
E-197 Trane Company 1985 BRAZED ALLUMINUM 012" 7' 6"
550 1100
E-508 Tulsa Multi Tube 1984 BEM 012" 26' Cold Liquid Exchanger 300 1200
E-511 Bes-Tex 1976 U-Tube 012" 23'
100 220
E-149 Cust-O-Fab 1976 CEN 012" 22' 0"
275 75
E-431 Waner MFG. 1982
012" 16'
50 75
E-219 Patterson-Kelly Co. 1982
012" 15'
100 50
E-278 Kemco 1961 Oil Reclaimer 012" 10' 8" 40,000 150 150 38
E-317 Shell & Tube 7-1982 BEM 012" 144" Air Heater 660 75 126
E-507 Tulsa Multi Tube 1984 BEM 012" 26' Cold Liquid Exchanger 300 1200
E-495 Bas-Tex 1976
012" 23'
100 220 1824sq.ft.
E-285 Shell & Tube 1970 BEM 012" 32' 2035 Sq. Ft. 200 275 2035
E-071 KEMCO 1964 HEAT EXCH. 012" 9' 7" 228,460 300 250 248
E-443 Slagle Mfg. 1970 BEM 012" 24'
1100 1100
E-319 Abbott Heat Exchanger 3- 1967 A.E.V. 013" 19' 3" MEA- Heat Exchanger 150 150 480
E-316 Shell & Tube 7-1982 BEM 013" 108" Acid Gas Heater 660 75 207
E-320 Abbott Heat Exchanger 3-1967 AEV 013" 19' 3" MEA-Heat Exchanger 150 150 480
E-492 EFCO 1971 NEN 013" 20 Ethane Exchanger 850 1440 404
E-416 Heat transfer systems 1984 BKU 013/28 19' 282 square feet 275 615
E-063 PATTERSON KELLEY CO. 1981 EXCH. 014" 13' 8"
300 125
E-082 KEMCO 1964 HEAT EXCH 014" 21' 6" 1,817,000 400 225 320
E-361 Western Supply 1993 U-Tube 014" 17' 238 Surface sq. ft. 600 515 238
E-510 Tulsa Multi Tube 1984 BEM 015" 32' cold gas exchanger 300 1200
E-509 Tulsa Multi Tube 1984 BEM 015" 32' gas/gas 300 1200
E-291 Shell & Tube 1970 BKM 015" 32' 254 Sq. Ft. 300 1100 254
E-151 Heat Exchanger Inc. 1971 Amine 015" 20' 0" 1,720,000 75 75 160 ft2
E-476 EFCO 1968 AES 015" 20'
75 100 662
E-502 Tulsa Multitube 1984 BEU 015" 20' Reboiler 300 1200
E-439 O'Neal's Welding 1990 AES 015" 24'
249 352
E-173 Texas Metal Fab. Co. 1963
015" 20' 0"
150 100
E-473 EFCO 1968 AES 015" 20'
75 100 662
E-267 TMT 1983 BEM 016" 14'
250 250
E-184 Western Suppy 1960 BKU 016" 10' 0"
125 350 314 Surface Area
E-266 Kemco 1975
016" 10' 2,900,000 1000 1000 140 SQ FT.
E-299 TMT 1983 BEM 017" 18'
250 250
E-474 Abbott 1968 AES 017" 24'
75 75
E-472 Abbott 1968 AES 017" 20'
75 75 739
E-490 EFCO 1971 NEN 017" 40' Low Temp. Gas Exch. 350 850 1712
E-360 Industrial Fab. 1965 CRJ 017" 14' 383 sq. ft. 600 575 383
E-462 Industial Fab. Co.

017" 14'
600 575
E-029 Heat Exchanger Inc. 1966 TUBES 017" 16' 0"
150 300 111.86 ft2
E-124 Conrad 1973 AEU 017" 16' 0"
215 190 471 est. sq/ft
E-506 Tulsa Multi Tube 1984 BE 017" 304 S.S. 12' Vert.Stabilizer Condenser 300 300
E-505 Tulsa Multi Tube
BKU 017"x33" 20' Horizontal Chiller 300 1200
E-143 Cust-O-Fab 1990 BEM 018" 36' 0"
250 420 1473
E-032 HEAT EXCHANGERS INC. 1966 TUBES 018" 20' 0"
400 300 1215 finned
E-237 Waner 1997
018" 20'
250 250
E-052 KEMCO 1980 BKU 018" 11' 6"
250 700 54
E-268 Kemco 1961 BEM 018" 32' 4,984,000 250 250 3240
E-366 Western Supply 1963 U-Tube 018" 14' 383 Surface Sq. Ft 600 575 383
E-349 Kemco 1996
018" 18' 7"
375 75
E-350 Kemco 1996
018" 18' 7"